TECHNICAL SPECIFICATIONS -- Kiosk'Ice US
Document Rev 4.0 -- March 2026
Kiosk'Ice US - Automated Ice Vending Machine - 3D View
Figure 1: Kiosk'Ice US -- Automated Ice Vending Machine

1. General Specifications

ModelKiosk'Ice US
ManufacturerMK ICE SAS, Ajaccio, France
Overall Dimensions (W x D x H)61.4 in x 44.9 in x 83.5 in (1560 x 1140 x 2120 mm)
Weight (empty)Approx. 882 lb (400 kg)
Operational Footprint42 sq ft minimum (including maintenance clearances)
Chassis Construction304 stainless steel frame and panels -- lifetime warranty on structural chassis
Repairability IndexAA++ (modular design, all components field-replaceable)
Output HatchEnlarged dispensing hatch accommodates bags (5-20 lb) and personal coolers
Thermal InsulationReinforced polyurethane foam, outdoor-rated for continuous sun exposure
Installation TypeFreestanding, outdoor unattended operation

2. Technical Drawings -- Elevations

Kiosk'Ice US - Front View
Figure 2: Front View
Kiosk'Ice US - Left Side View
Figure 3: Left Side View
Kiosk'Ice US - Right Side View
Figure 4: Right Side View
Kiosk'Ice US - Top View
Figure 5: Top View
Kiosk'Ice US - Full Technical Schemas
Figure 6: Complete Schema Overview -- All Elevations

3. Ice Production System

Scotsman NW 1008 Ice Machine
Figure 7: Scotsman NW 1008 AS -- Ice Production Module
Scotsman Dice Ice Cube 10g
Figure 8: Dice Ice Cube -- 7/8 in, 0.35 oz (10 g)
Ice Production ModuleScotsman NW 1008 AS (OEM integrated)
Maximum Production Rate1,005 lb / 24 h (456 kg / 24 h)
Integrated Storage Capacity485 lb (220 kg)
Ice TypeDice -- 7/8 in (22 mm) cube, 0.35 oz (10 g) per piece
RefrigerantR404A / R452A (transition-ready)
Condenser VentilationEnhanced airflow design for high ambient temperatures
Hygiene SystemXSafe integrated UV-C sanitation -- 24/7 continuous operation
Ice Contact SurfacesFood-grade stainless steel and FDA-compliant polymers

4. Electrical Specifications

Power Supply230V AC, single phase, 60 Hz
Maximum Amperage15 A
Energy per 220 lb of Ice13.1 kWh
Maximum Daily Energy Consumption49.9 kWh (at peak production, 104 F ambient)
Circuit Breaker (recommended)20 A dedicated circuit
Power ConnectionHardwired or NEMA 6-20P plug (consult installer)

5. Water Supply Requirements

Water Consumption5.9 gal/h (22.3 L/h) at peak production
Supply Pressure14 -- 70 psi (1 -- 5 bar)
Inlet Water Temperature41 -- 95 F (5 -- 35 C)
Connection Type3/4 in NPT male fitting, braided stainless supply line recommended
Drain1 in gravity drain or condensate pump (site-dependent)
Water QualityPotable municipal water; filtration system included

6. Operating Conditions

Ambient Air Temperature50 -- 104 F (10 -- 40 C)
Inlet Water Temperature41 -- 95 F (5 -- 35 C)
Relative HumidityUp to 90% non-condensing
Installation EnvironmentOutdoor, unattended, continuous 24/7 operation
Wind ResistanceRated for sustained winds up to 60 mph when properly anchored
Surface RequirementLevel concrete pad, minimum 4 in thickness

7. Maintenance Zones and Clearances

Kiosk'Ice US - Top View Maintenance Zone
Figure 9: Top View -- Maintenance Clearance Zones
Kiosk'Ice US - Front View Maintenance Zone
Figure 10: Front View -- Maintenance Access Zones
Left Clearance16.3 in (414 mm) minimum
Right Clearance16.3 in (414 mm) minimum
Top Clearance42.6 in (1082 mm) minimum
Front Clearance40.5 in (1029 mm) minimum
Rear Clearance3.9 in (100 mm) minimum

All maintenance operations -- including ice machine servicing, filter replacement, payment terminal access, and electrical panel inspection -- are performed from the front and sides of the unit. The rear clearance of 3.9 in is required solely for ventilation and condensate drainage. Left and right clearances of 16.3 in each allow full panel removal for access to internal components. The top clearance of 42.6 in accommodates the upper panel lift required during ice machine extraction or replacement. The front clearance of 40.5 in provides the working space necessary for a technician to perform routine and corrective maintenance safely. All clearance dimensions must be maintained free of obstructions at all times.

8. Interface and Payment

Payment TerminalPAX IM30 (integrated, PCI PTS 6.x compliant)
Payment MethodsContactless NFC (Apple Pay, Google Pay), chip (EMV), magnetic stripe, credit/debit cards
Dispense TriggerPhysical push-button (illuminated, vandal-resistant)
Customer Display7 in color LCD -- product selection, pricing, transaction status
ReceiptDigital receipt via email or SMS (no paper printer)
ADA ComplianceControls and hatch positioned per ADA reach-range guidelines

9. Connectivity

Network InterfacesRJ45 Ethernet, 4G LTE, 5G-ready, WiFi 802.11ac
Monitoring PlatformKiosk'Ice Business (cloud-based SaaS dashboard)
AlertsReal-time notifications: equipment faults, low ice, door open, payment errors
OTA UpdatesRemote firmware and software updates via secure channel (TLS 1.3)
TelemetryIce level, production rate, ambient/internal temperatures, energy consumption, transaction logs
API IntegrationREST API available for third-party fleet management systems

10. Certifications and Compliance

The Kiosk'Ice US model is specifically adapted for the American market. The unit is engineered to comply with applicable US electrical standards (UL/CSA), food safety regulations (FDA 21 CFR, NSF/ANSI standards for commercial ice equipment), and commercial vending equipment requirements. The payment system meets PCI DSS and PCI PTS certification requirements for unattended payment terminals. Electrical components are rated for 230V/60Hz operation per NEC guidelines. Contact the manufacturer directly at [email protected] for the current and complete list of certifications, test reports, and compliance documentation applicable to your state and jurisdiction.